Skip to content

DS1307 RTC Module - Real-Time Clock

Overview

The DS1307 RTC is a real-time clock module used to keep track of time while the main microcontroller is powered off.

It uses a backup coin-cell battery and communicates over I2C.

In this course it is used to:

  • Practice I2C communication
  • Read and set date/time values
  • Learn battery-backed peripherals
  • Display time on an OLED
  • Build simple data logging examples

Image

DS1307 RTC module


Key Specifications

  • Type: Real-time clock module
  • Main supply voltage: typically 5V for many DS1307 modules (3V3 compatible)
  • I2C address: 0x68
  • Backup battery: usually CR2032
  • Timekeeping: seconds, minutes, hours, day, date, month, year
  • Clock source: 32.768kHz crystal
  • Optional output: square-wave pin

⚠ The DS1307 chip is a 5V part. Check module pull-ups before connecting I2C lines to a 3.3V MCU.


How It Works

The DS1307 counts time using a 32.768kHz crystal.

The module:

  • Stores time and date in internal registers
  • Keeps running from the backup battery when main power is off
  • Communicates with the MCU over I2C
  • Uses BCD format internally for time values

Most libraries handle the BCD conversion automatically.


Basic Circuit / Connection

DS1307 RTC schematic

Typical wiring:

DS1307 Pin ESP32-S3 / STM32F411 Connection Notes
VCC 5V or module-required supply Check module
GND GND Common ground
SDA I2C SDA Check pull-up voltage
SCL I2C SCL Check pull-up voltage
SQW Optional GPIO input Square-wave output

For 3.3V boards, make sure SDA and SCL are not pulled up to 5V.


Important Electrical Notes

  • I2C address is fixed at 0x68.
  • Many DS1307 modules have pull-up resistors to VCC.
  • If VCC is 5V and pull-ups go to 5V, use a level shifter or modify the pull-ups.
  • The backup battery keeps the clock running, but it should not power the whole module.
  • The RTC must be set at least once before it can report the correct time.
  • DS1307 is less accurate than temperature-compensated RTCs such as DS3231.

Basic Calculations

I2C Pull-up Current

For a 4.7k ohm pull-up to 3.3V:

\[ I = \frac{3.3}{4700} \approx 0.7mA \]

For a pull-up to 5V:

\[ I = \frac{5}{4700} \approx 1.1mA \]

The current is not the main problem. The voltage level is. A 5V pull-up can damage or stress 3.3V-only GPIO pins.

Clock Drift

If an RTC drifts 20ppm:

\[ 20ppm = 20 \text{ seconds per } 1,000,000 \text{ seconds} \]

That is roughly:

\[ 1.7 \text{ seconds per day} \]

Real modules can be better or worse depending on crystal quality and temperature.


Typical Use in This Course

  • Set the RTC time from firmware
  • Read date and time over I2C
  • Display time on SSD1306 OLED
  • Timestamp sensor measurements
  • Compare RTC timekeeping with MCU timers

Common Student Mistakes

  • Forgetting to install the backup battery
  • Not setting the RTC time before reading it
  • Using 5V I2C pull-ups with 3.3V GPIO pins
  • Mixing up SDA and SCL
  • Expecting perfect long-term accuracy
  • Ignoring the fixed I2C address when multiple devices are used

Advantages

  • Keeps time while MCU is off
  • Simple I2C interface
  • Very common module
  • Useful for logging and clocks
  • Includes battery backup

Limitations

  • DS1307 usually needs 5V supply
  • I2C pull-up voltage must be checked
  • Less accurate than DS3231
  • Requires a coin-cell battery
  • Does not know real time until set

Datasheet

Analog Devices / Maxim DS1307 datasheet:


Summary

The DS1307 RTC module is used for timekeeping:

  • Communicates over I2C at address 0x68
  • Uses a backup battery
  • Must be checked carefully with 3.3V boards
  • Is useful for clocks, logs, and timestamped sensor projects