Skip to content

Relay Module - Isolated Switching Module

Overview

A single relay module is an electrically controlled switch.

It allows a microcontroller to control a separate circuit that may use a different voltage or a higher current than the MCU GPIO can handle.

In this course it is used to:

  • Practice digital output control
  • Switch external loads safely
  • Understand isolation between control and load circuits
  • Learn why inductive loads need protection

Image

Single relay module


Key Specifications

  • Type: Electromechanical relay module
  • Control input: usually 3.3V or 5V logic depending on module
  • Relay coil voltage: usually 5V
  • Load contacts: often rated around 10A at 250VAC or 10A at 30VDC
  • Output contacts:
    • COM (Common)
    • NO (Normally Open)
    • NC (Normally Closed)
  • Input behavior: many modules are active LOW

⚠ Contact ratings are maximum values. For beginner projects, use low-voltage DC loads whenever possible.


How It Works

A relay contains a coil and mechanical contacts.

When current flows through the coil:

  • A magnetic field is created
  • The internal switch moves
  • COM connects to NO instead of NC

Contact meanings:

Contact Meaning State when relay is OFF
COM Common terminal Connected to NC
NO Normally Open Disconnected
NC Normally Closed Connected to COM

Basic Circuit / Connection

Relay module schematic

Typical control-side wiring:

Relay Pin ESP32-S3 / STM32F411 Connection
VCC 5V module supply
GND GND
IN GPIO output

Typical load-side wiring:

  • COM -> external power source
  • NO -> load input
  • Load output -> external power ground or return

Use NO when the load should be normally OFF.


Important Electrical Notes

  • A relay coil needs much more current than a GPIO pin can provide directly.
  • Use a relay module with a driver transistor, flyback diode, and proper input circuit.
  • Many 5V relay modules do not switch reliably from a 3.3V GPIO.
  • Always connect a common ground between MCU and relay module control side, unless the module is intentionally wired for optical isolation.
  • Keep mains voltage away from breadboards and beginner lab wiring.
  • Relay contacts are isolated from the control input, but the PCB spacing still matters for safety.
  • Mechanical relays are slow compared with transistors or MOSFETs.

Basic Calculations

For relay modules, the most important calculation is usually supply current.

If the relay coil consumes 70mA from 5V:

\[ P = V \cdot I = 5 \cdot 0.07 = 0.35W \]

This is far above what an MCU GPIO can provide.

A GPIO should only drive the module input, not the relay coil directly.


Typical Use in This Course

  • Turning a low-voltage load ON and OFF
  • Learning active LOW output behavior
  • Understanding COM, NO, and NC contacts
  • Comparing relay switching with transistor switching

Common Student Mistakes

  • Powering the relay coil from a GPIO pin
  • Forgetting common ground on the control side
  • Assuming every relay module accepts 3.3V input
  • Wiring the load to NC when NO was intended
  • Switching too fast and wearing out the relay
  • Using a breadboard for high-current or mains loads

Advantages

  • Provides electrical isolation between control and load circuits
  • Can switch AC or DC loads
  • Easy to understand as an actual switch
  • Useful for learning load control

Limitations

  • Mechanical wear over time
  • Makes clicking noise
  • Slow switching speed
  • Coil consumes noticeable current
  • Not suitable for PWM speed or brightness control

Summary

The single relay module is a practical output module:

  • Uses a small GPIO signal to switch a separate load
  • Has COM, NO, and NC contacts
  • Requires correct module supply and safe wiring
  • Good for ON/OFF control, not PWM